Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Anal Toxicol ; 41(2): 146-152, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27881619

RESUMO

The present study proposed the use of liquid chromatography-tandem mass spectrometry to detect the novel ß-agonist phenylethanolamine A (PEA) in incurred hair samples of swine and sheep and to assess its accumulation for residue monitoring. The method showed good percent recoveries ranging from 93.2% to 102% and good coefficient of variation at <15%. The experiment was conducted in swine (24 treated and 4 controls) and sheep (3 treated and 1 control). PEA concentration was determined in hair during the treatment. High residue concentrations were present in hair as early as Day 24 (14.8 ± 3.6 and 25.8 ± 7.6 ng/g) and Day 21 (23.4 ± 6.6 ng/g) for swine and sheep; these residues persisted until withdrawal on Days 14 and 21. Results showed high PEA accumulation in hair, thereby indicating the use of hair as a matrix in the control of PEA abuse in farm animals.


Assuntos
2-Hidroxifenetilamina/análogos & derivados , Agonistas Adrenérgicos beta/análise , Resíduos de Drogas/análise , Cabelo/química , Detecção do Abuso de Substâncias/métodos , Detecção do Abuso de Substâncias/veterinária , 2-Hidroxifenetilamina/análise , Animais , Cromatografia Líquida , Feminino , Masculino , Ovinos , Detecção do Abuso de Substâncias/instrumentação , Suínos , Espectrometria de Massas em Tandem
2.
J Pharm Biomed Anal ; 114: 12-5, 2015 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-25988297

RESUMO

A new method for determining salbutamol in hair of sheep by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was established. Samples were extracted with 0.1M of HCl solution. The mixture was heated to 60 °C in a water bath and kept at this temperature for 4h. The extracts were purified through SPE method and then dried with nitrogen. Residues were redissolved in mobile phase. The target compound was determined by UPLC-MS/MS with BEH-C18 column. The usefulness and feasibility of different treatment procedures of hair containing salbutamol were evaluated. The range of linearity was 1-100 ng/g. The LOD was 0.3 ng/g, and the LOQ was 1 ng/g. Recoveries were 89-106%, and coefficients of variation were 3.2-13.9%. Pharmacokinetics of salbutamol was studied in healthy sheep after oral administration of 150 µg/kg body weight salbutamol for 21 consecutive days. Salbutamol residues in hair were still detected after 21 days of administration.


Assuntos
Albuterol/análise , Albuterol/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Cabelo/química , Espectrometria de Massas em Tandem/métodos , Administração Oral , Animais , Ácido Clorídrico/química , Limite de Detecção , Nitrogênio/química , Reprodutibilidade dos Testes , Ovinos , Solventes/química , Temperatura
3.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-455354

RESUMO

Objective To investigate the safety and efficacy of laparoscopic complete mesocolic excision (CME) with a medial-to-lateral approach for the treatment of right colonic cancer.Methods The clinical data of 46 patients with right colonic cancer who were admitted to the Longjiang Hospital from January 2010 to October 2013 were retrospectively analyzed.Twenty-four patients who received laparoscopic CME were in the laparoscopic group,and the other 22 patients who received open CME were in the control group.The intra-and postoperative condition and tumor recurrence of the 2 groups were compared.Patients were followed up till April 2014 after the operation.The measurement data were analyzed using the t test,and the count data were analyzed using the chi square test or Fisher exact probability.Results The operation was successfully done in the 2 groups.The operation time and intraoperative blood loss were (130 ± 26) minutes and (105 ± 29) mL in the laparoscopic group,and (156 ± 32)minutes and (136 ± 35)mL in the control group,with significant differences between the 2 groups (t =6.070,3.310,P<0.05).The numbers of lymph nodes resected and lengths of resected specimen were 19 ± 4 and (28.0 ± 2.5)cm in the laparoscopic group,and 18 ± 4 and (26.8 ± 2.3)cm in the control group,with no significant differences between the 2 groups (t =0.560,1.770,P >0.05).The postoperative exhaust time and duration of postoperative hospital stay were (2.9 ±0.8)days and (12.3 ±2.7) days in the laparoscopic group,and (3.8 ±0.9)days and (14.1 ±2.2) days in the control group,with significant differences between the 2 groups (t =3.880,2.400,P < 0.05).No operation-related complications was detected in the 2 groups.Forty-six patients were followed up for a mean time of 15 months (range,6-24 months).Two patients in the laparoscopic group and 2 in the control group were complicated with tumor local recurrence,with no significant difference between the 2 groups (P > 0.05).No patients died during the follow-up.Conclusion Laparoscopic complete mesorectal excision with a medial-to-lateral approach for right colonic cancer is safe and feasible with satisfactory short-term outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...